Digital BUS-WATCH
®
HDx00
Page 68 of 85
Radio Engineering Industries, Inc.
640430 -- Rev 0 -- 1/12/2012
Figure 56: Accelerometer Setup
The Accelerometer Setup Menu gives user options to configure accelerometer.
Calibrate Accelerometer: accelerometer must be calibrated after installation.
Select Calibrate Accelerometer to calibrate accelerometer.
Current Values: current acceleration readings from the accelerometer.
Accel Alarm Sensitivity: DVR gives three options to configure how the
accelerometer triggers alarm.
When set to Preset, DVR enables the presets selection box. User can select from 1
to 9 for the most suitable sensitivity.
Figure 57: Accelerometer Sensitivity
When set to Manual, DVR allows user to enter threshold valves on each axis.